The UniCAN data loggers of CSM are stand-alone loggers, based on the CAN bus and have two to four CAN 2.0 B interfaces.
Remote access is possible via GPS/GPRS for all loggers, while GPS and UMTS are possible for the versions 2 of the loggers. Data analysis can be done by downloading the logged data to software packages like MS Excel, DIAdem. Labview, INCA, CANoe, CANalyzer, EDAS Win and others. The interface via RS232 has a maximum Baut Rate of 115.200. The maximum sample rate is 1 MBit/sec.
At the moment there are three different types of CAM UniCAN data loggers available. For all models several options and accessories are available. Ask for the possibilities. A UniCAN configuration tool will be part of the delivery.
Input data
Output data
Limitations
Availability/licensing for 3rd parties
Contact information
Name | |
Contact website | http://www.csm.de |
Product website | http://www.csm.de/en/measurement-technology/data-loggers/unican-2.html |
Additional notes
Hardware
- Number of CAN channels: 3
- Memory: ATA flash card type II
- GPRS/GSM: optional
- GPS: no
- WLAN: no
- LAN: no
- Interfaces: 4x subd9 3-pin low voltage connector
- Casing: robust metal casing
- Input: 8-32 V
Other
- Size: 109x35x176 mm
- Prize: tbc
- Other inputs: no
- Other outputs: no
- Consumption idle: 2ma at 12V (=24 mW)
- Consumption on: 1.6 W
- Energy Save: yes
- Filtering: yes
- Triggering: yes
- Diagnose: optional
- Audio: no