UniCAN 2 Professional

From FOT-Net WIKI
Jump to navigationJump to search
UniCAN 2 Professional
Logo csm.jpg
Provider / Developer CSM GmbH - Computer-Systeme-Messtechnik
Category Data acquisition
Purpose of tool CAN data collection
Type of analysis
Graphical User Interface (GUI) No
Operatin systems / platforms Windows
Work mode
Open source No
Typical users
Release date
Last updated 02/2013
Used in projects

The UniCAN data loggers of CSM are stand-alone loggers, based on the CAN bus and have two to four CAN 2.0 B interfaces.

UniCAN 2 Professional is a µ-Controller based stand-alone data logger. It has unique features and capabilities which are otherwise found only in high end devices. It offers two different methods for a fast, safe and convenient configuration: CompactFlash cards up to 128 GB, GPRS, EDGE and UMTS/3G. UniCAN 2 Professional enables simultaneously time-based recording of signals in up to 8 separate channel groups and the event-driven recording of CAN messages (Trace) in up to 8 separate message groups.

Input data

Output data

Limitations

Availability/licensing for 3rd parties

Contact information

Name
E-mail info@csm.de
Contact website http://www.csm.de
Product website

Additional notes

Hardware

  • Number of CAN channels: Up to 4 x CAN 2.0b HS(ISO 11898-2), max. 1 MBit/s, LS(ISO 11898-3)
  • Memory: CF Card up to 128 Gb
  • GPRS/GSM: optional
  • GPS: optional
  • USB: yes
  • WLAN: no
  • LAN: no
  • Interfaces: HS CAN(ISO 11898-2), max. 1 MBit/s, LS CAN (ISO 11898-3)
  • Casing: Metal Case
  • Input: 6.5 V to 50 V DC

Other

  • Size: 109x35x150 mm (500g.)
  • Other inputs: 4 available digital I/O - up to 4 x digital IN (TTL-threshold)
  • Other outputs: up to 2 x digital OUT
  • Consumption idle: Stand-by current (PowerControl OFF) < 500 µA at 12 V (< 6 mW)
  • Consumption on: approx. 3 W (in operation, without options)